Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 120
Filtrar
1.
Pediatr Radiol ; 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38488925

RESUMO

Magnetic resonance imaging (MRI) is now an indispensable diagnostic tool in medicine due to its outstanding contrast resolution and absence of radiation exposure, enabling detailed tissue characterization and three-dimensional anatomical representation. This is especially important when evaluating individuals with congenital heart disease (CHD) who frequently require cardiac implantable electrical devices (CIEDs). While MRI safety issues have previously limited its use in patients with CIEDs, new advances have called these limitations into question. However, difficulties persist in the pediatric population due to the continued lack of specific safety data both related to imaging young children and the specific CIED devices they often require. This paper discusses MRI safety considerations related to imaging patients with CIEDs, investigates pediatric-specific problems, and describes thorough methods for safe MRI access, highlighting the significance of specialized institutional guidelines.

4.
JACC Clin Electrophysiol ; 10(3): 539-550, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38206260

RESUMO

BACKGROUND: Evidence for the efficacy of cardiac resynchronization therapy (CRT) in pediatric and congenital heart disease (CHD) has been limited to surrogate outcomes. OBJECTIVES: This study aimed to assess the impact of CRT upon the risk of transplantation or death in a retrospective, high-risk, controlled cohort at 5 quaternary referral centers. METHODS: Both CRT patients and control patients were <21 years of age or had CHD; had systemic ventricular ejection fraction <45%; symptomatic heart failure; and significant electrical dyssynchrony (QRS duration z score >3 or single-site ventricular pacing >40%) at enrollment. Patients with CRT were matched with control patients via 1:1 propensity score matching. CRT patients were enrolled at CRT implantation; control patients were enrolled at the outpatient clinical encounter where inclusion criteria were first met. The primary endpoint was transplantation or death. RESULTS: In total, 324 control patients and 167 CRT recipients were identified. Mean follow-up was 4.2 ± 3.7 years. Upon propensity score matching, 139 closely matched pairs were identified (20 baseline indices). Of the 139 matched pairs, 52 (37.0%) control patients and 31 (22.0%) CRT recipients reached the primary endpoint. On both unadjusted and multivariable Cox regression analysis, the risk reduction associated with CRT for the primary endpoint was significant (HR: 0.40; 95% CI: 0.25-0.64; P < 0.001; and HR: 0.44; 95% CI: 0.28-0.71; P = 0.001, respectively). On longitudinal assessment, the CRT group had significantly improved systemic ventricular ejection fraction (P < 0.001) and shorter QRS duration (P = 0.015), sustained to 5 years. CONCLUSIONS: In pediatric and CHD patients with symptomatic systolic heart failure and electrical dyssynchrony, CRT was associated with improved heart transplantation-free survival.


Assuntos
Terapia de Ressincronização Cardíaca , Cardiopatias Congênitas , Insuficiência Cardíaca Sistólica , Transplante de Coração , Humanos , Criança , Estudos Retrospectivos , Cardiopatias Congênitas/terapia , Insuficiência Cardíaca Sistólica/terapia
5.
Heart Rhythm ; 2024 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-38246569

RESUMO

BACKGROUND: The Apple Watch™ (AW) offers heart rate (HR) tracking by photoplethysmography (PPG) and single-lead electrocardiographic (ECG) recordings. The accuracy of AW-HR and diagnostic performance of AW-ECGs among children during both sinus rhythm and arrhythmias have not been explored. OBJECTIVE: The purposes of this study were to assess the accuracy of AW-HR measurements compared to gold standard modalities in children during sinus rhythm and arrhythmias and to identify non-sinus rhythms using AW-ECGs. METHODS: Subjects ≤18 years wore an AW during (1) telemetry admission, (2) electrophysiological study (EPS), or (3) exercise stress test (EST). AW-HRs were compared to gold standard modality values. Recorded AW-ECGs were reviewed by 3 blinded pediatric electrophysiologists. RESULTS: Eighty subjects (median age 13 years; interquartile range 1.0-16.0 years; 50% female) wore AW (telemetry 41% [n = 33]; EPS 34% [n = 27]; EST 25% [n = 20]). A total of 1090 AW-HR measurements were compared to time-synchronized gold standard modality HR values. Intraclass correlation coefficient (ICC) was high 0.99 (0.98-0.99) for AW-HR during sinus rhythm compared to gold standard modalities. ICC was poor comparing AW-HR to gold standard modality HR in tachyarrhythmias (ICC 0.24-0.27) due to systematic undercounting of AW-HR values. A total of 126 AW-ECGs were reviewed. Identification of non-sinus rhythm by AW-ECG showed sensitivity of 89%-96% and specificity of 78%-87%. CONCLUSIONS: We found high levels of agreement for AW-HR values with gold standard modalities during sinus rhythm and poor agreement during tachyarrhythmias, likely due to hemodynamic effects of tachyarrhythmias on PPG-based measurements. AW-ECGs had good sensitivity and moderate specificity in identification of non-sinus rhythm in children.

6.
Card Electrophysiol Clin ; 15(4): 421-432, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37865516

RESUMO

Transcatheter leadless pacemakers have benefits in congenital heart disease because they eliminate the risks of lead malfunction, venous occlusions, and pocket complications. This newest pacemaker's utility in this population has been limited by the large sheath and delivery system, need for atrioventricular synchronous pacing, lack of explantation options, and possible lack of adequate access to the subpulmonary ventricle. With careful planning, leadless pacing can be successfully performed in these patients. Consideration of nonfemoral access, alternative implant sites to avoid myocardial scar or prosthetic material, anticoagulation for patients with persistent intracardiac shunts or systemic ventricular implantation, and operator experience are critical.


Assuntos
Cardiopatias Congênitas , Marca-Passo Artificial , Humanos , Estimulação Cardíaca Artificial , Ventrículos do Coração , Cardiopatias Congênitas/terapia , Miocárdio
8.
Pediatr Cardiol ; 2023 Sep 09.
Artigo em Inglês | MEDLINE | ID: mdl-37684488

RESUMO

Hypertrophic cardiomyopathy (HCM), a common cardiomyopathy in children, is an important cause of morbidity and mortality. Early recognition and appropriate management are important. An electrocardiogram (ECG) is often used as a screening tool in children to detect heart disease. The ECG patterns in children with HCM are not well described.ECGs collected from an international cohort of children, and adolescents (≤ 21 years) with HCM were reviewed. 482 ECGs met inclusion criteria. Age ranged from 1 day to 21 years, median 13 years. Of the 482 ECGs, 57 (12%) were normal. The most common abnormalities noted were left ventricular hypertrophy (LVH) in 108/482 (22%) and biventricular hypertrophy (BVH) in 116/482 (24%) Of the patients with LVH/BVH (n = 224), 135 (60%) also had a strain pattern (LVH in 83, BVH in 52). Isolated strain pattern (in the absence of criteria for hypertrophy) was seen in 43/482 (9%). Isolated pathologic Q waves were seen in 71/482 (15%). Pediatric HCM, 88% have an abnormal ECG. The most common ECG abnormalities were LVH or BVH with or without strain. Strain pattern without hypertrophy and a pathologic Q wave were present in a significant proportion (24%) of patients. Thus, a significant number of children with HCM have ECG abnormalities that are not typical for "hypertrophy". The presence of the ECG abnormalities described above in a child should prompt further examination with an echocardiogram to rule out HCM.

9.
Heart Rhythm ; 20(12): 1752-1758, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37648183

RESUMO

BACKGROUND: Guidelines addressing magnetic resonance imaging (MRI) in patients with cardiac implantable electronic devices (CIEDs) provide algorithms for imaging pediatric and congenital heart disease (CHD) patients. Guideline acceptance varies by institution. Guidelines also do not support routine MRI scans in patients with epicardial or abandoned leads, common in pediatric and CHD patients. OBJECTIVE: The purpose of this study was to determine the incidence of MRI-related complications in pediatric and CHD patients with CIEDs, including epicardial and/or abandoned leads. METHODS: A multicenter retrospective review included patients with CIEDs who underwent any MRI between 2007 and 2022 at congenital cardiac centers. The primary outcome was any patient adverse event or clinically significant CIED change after MRI, defined as pacing lead capture threshold increase >0.5 V with output change, P- or R- wave amplitude decrease >50% with sensitivity change, or impedance change >50%. RESULTS: Across 14 institutions, 314 patients (median age 18.8 [1.3; 31.4] years) underwent 389 MRIs. There were 288 pacemakers (74%) and 87 implantable cardioverter-defibrillators (22%); 52% contained epicardial leads, and 14 (4%) were abandoned leads only. Symptoms or CIED changes occurred in 4.9% of MRI scans (6.1% of patients). On 9 occasions (2%), warmth or pain occurred. Pacing capture threshold or lead impedance changes occurred in 1.4% and 2.0% of CIEDs post-MRI and at follow-up. CONCLUSION: Our data provide evidence that MRIs can be performed in pediatric and CHD patients with CIEDs, including non-MRI-conditional CIEDs and epicardial and/or abandoned leads, with rare minor symptoms or CIED changes but no other complications.


Assuntos
Desfibriladores Implantáveis , Cardiopatias Congênitas , Marca-Passo Artificial , Adolescente , Criança , Humanos , Cardiopatias Congênitas/diagnóstico , Cardiopatias Congênitas/terapia , Imageamento por Ressonância Magnética/métodos , Estudos Retrospectivos , Lactente , Pré-Escolar , Adulto Jovem , Adulto
10.
Pediatr Cardiol ; 2023 Aug 06.
Artigo em Inglês | MEDLINE | ID: mdl-37544951

RESUMO

BACKGROUND: Published guidelines provide recommendations for risk stratification in pediatric Wolff-Parkinson-White (WPW). There are no data on provider concordance with these guidelines. We hypothesized that significant practice variation exists between pediatric cardiologists (PC) and electrophysiologists (EP). METHOD: The records of all patients, age 8 to 21 years, with a new ECG diagnosis of WPW between 1/1/2013 and 12/31/2018, from a single center, were retrospectively reviewed. Subjects were categorized on the basis of symptoms and resting ECG findings as one of the following: asymptomatic intermittent WPW, asymptomatic persistent WPW, or symptomatic WPW. The performance and results of diagnostic testing, including Holter monitor, event monitor, exercise stress test (EST), and electrophysiology study (EPS), were recorded. The primary outcome was concordance with published guidelines. A secondary outcome was documentation of a discussion of sudden cardiac death (SCD) risk. RESULTS: 615 patient encounters were analyzed in 231 patients with newly diagnosed WPW pattern on ECG (56% male; mean age at diagnosis 13.9 ± 2.5 years). EP were observed to have a significantly higher rate of guideline concordance than PC (95% vs. 71%, p < 0.001). There was significant practice variation between PC and EP in the documentation of a discussion of SCD risk: 96% in EP vs. 39% in PC (p < 0.001). CONCLUSION: Significant practice variation exists in the non-invasive and invasive risk stratification of pediatric WPW, with lower concordance to published guidelines amongst PC, when compared to EP. This report highlights the need to promote awareness of current WPW guidelines in the pediatric cardiology community at large.

12.
Circ Arrhythm Electrophysiol ; 16(4): e011447, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-37039017

RESUMO

BACKGROUND: Transcatheter Leadless Pacemakers (TLP) are a safe and effective option for adults with pacing indications. These devices may be an alternative in pediatric patients and patients with congenital heart disease for whom repeated sternotomies, thoracotomies, or transvenous systems are unfavorable. However, exemption of children from clinical trials has created uncertainty over the indications, efficacy, and safety of TLP in the pediatric population. The objectives of this study are to evaluate clinical indications, procedural characteristics, electrical performance, and outcomes of TLP implantation in children. METHODS: Retrospective data were collected from patients enrolled in the Pediatric and Congenital Electrophysiology Society TLP registry involving 15 centers. Patients ≤21 years of age who underwent Micra (Medtronic Inc, Minneapolis, MN) TLP implantation and had follow-up of ≥1 week were included in the study. RESULTS: The device was successfully implanted in 62 of 63 registry patients (98%) at a mean age of 15±4.1 years and included 20 (32%) patients with congenital heart disease. The mean body weight at TLP implantation was 55±19 kg and included 8 patients ≤8 years of age and ≤30 kg in weight. TLP was implanted by femoral (n=55, 87%) and internal jugular (n=8, 12.6%) venous approaches. During a mean follow-up period of 9.5±5.3 months, there were 10 (16%) complications including one cardiac perforation/pericardial effusion, one nonocclusive femoral venous thrombus, and one retrieval and replacement of TLP due to high thresholds. There were no deaths, TLP infections, or device embolizations. Electrical parameters, including capture thresholds, R wave sensing, and pacing impedances, remained stable. CONCLUSIONS: Initial results from the Pediatric and Congenital Electrophysiology Society TLP registry demonstrated a high level of successful Micra device implants via femoral and internal venous jugular approaches with stable electrical parameters and infrequent major complications. Long-term prospective data are needed to confirm the reproducibility of these initial findings.


Assuntos
Cardiopatias Congênitas , Marca-Passo Artificial , Adulto , Humanos , Criança , Adolescente , Adulto Jovem , Recém-Nascido , Estudos Prospectivos , Estudos Retrospectivos , Reprodutibilidade dos Testes , Resultado do Tratamento , Desenho de Equipamento , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Cardiopatias Congênitas/diagnóstico , Cardiopatias Congênitas/terapia
13.
JACC Clin Electrophysiol ; 9(3): 385-393, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36752449

RESUMO

BACKGROUND: Dyssynchrony-associated left ventricular systolic dysfunction is a major contributor to heart failure in congenital heart disease (CHD). Although conventional cardiac resynchronization therapy (CRT) has shown benefit, the comparative efficacy of cardiac conduction system pacing (CSP) is unknown. OBJECTIVES: The purpose of this study was compare the clinical outcomes of CSP vs conventional CRT in CHD with biventricular, systemic left ventricular anatomy. METHODS: Retrospective CSP data from 7 centers were compared with propensity score-matched conventional CRT control subjects. Outcomes were lead performance, change in left ventricular ejection fraction (LVEF), and QRS duration at 12 months. RESULTS: A total of 65 CSP cases were identified (mean age 37 ± 21 years, 46% men). The most common CHDs were tetralogy of Fallot (n = 12 [19%]) and ventricular septal defect (n = 12 [19%]). CSP was achieved after a mean of 2.5 ± 1.6 attempts per procedure (38 patients with left bundle branch pacing, 17 with HBP, 10 with left ventricular septal myocardial). Left bundle branch area pacing [LBBAP] vs HBP was associated with a smaller increase in pacing threshold (Δ pacing threshold 0.2 V vs 0.8 V; P = 0.05) and similar sensing parameters at follow-up. For 25 CSP cases and control subjects with baseline left ventricular systolic dysfunction, improvement in LVEF was non-inferior (Δ LVEF 9.0% vs 6.0%; P = 0.30; 95% confidence limits: -2.9% to 10.0%) and narrowing of QRS duration was more pronounced for CSP (Δ QRS duration 35 ms vs 14 ms; P = 0.04). Complications were similar (3 [12%] CSP, 4 [16%] conventional CRT; P = 1.00). CONCLUSIONS: CSP can be reliably achieved in biventricular, systemic left ventricular CHD patients with similar improvement in LVEF and greater QRS narrowing for CSP vs conventional CRT at 1 year. Among CSP patients, pacing electrical parameters were superior for LBBAP vs HBP.


Assuntos
Terapia de Ressincronização Cardíaca , Cardiopatias Congênitas , Disfunção Ventricular Esquerda , Masculino , Humanos , Adolescente , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Feminino , Terapia de Ressincronização Cardíaca/efeitos adversos , Bloqueio de Ramo , Fascículo Atrioventricular , Volume Sistólico , Estudos Retrospectivos , Eletrocardiografia , Função Ventricular Esquerda , Resultado do Tratamento , Doença do Sistema de Condução Cardíaco , Cardiopatias Congênitas/complicações , Cardiopatias Congênitas/terapia , Disfunção Ventricular Esquerda/terapia
14.
JACC Clin Electrophysiol ; 9(1): 73-84, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36697203

RESUMO

BACKGROUND: Guidelines for electrophysiology study (EPS) and catheter ablation in Wolff-Parkinson-White (WPW) are age based, but size may be a more relevant factor in determination of outcomes. OBJECTIVES: The goal of this study was to evaluate the association of patient weight with outcomes of catheter ablation for pediatric WPW. METHODS: A multicenter retrospective cohort study was performed on children aged 1 to 21 years with WPW and first-time EPS from April 2016 to December 2019 recorded in the IMPACT (Improving Pediatric and Adult Congenital Treatment) registry, excluding those with congenital heart disease, cardiomyopathy, and >1 ablation target. A weight threshold of 30 kg was selected, representing 1 SD below the cohort mean. The primary outcome was major adverse events (MAEs); additional outcomes included deferred ablation, use of cryoablation, and ablation success. RESULTS: A total of 4,456 subjects from 84 centers were evaluated, with 14% weighing <30 kg. Subjects weighing <30 kg were more likely to have preprocedural supraventricular tachycardia (45% vs 29%; P < 0.001) and less likely to have right septal accessory pathways (25% vs 33%; P < 0.001). MAEs were rare, although with higher incidence in the <30 kg cohort (0.3% vs 0.05%; P = 0.04). No difference was seen in likelihood of deferred ablation (9% vs 12%; P = 0.07) or use of cryoablation (11% vs 11%; P = 0.70). Success was higher in the <30 kg cohort: 95% vs 92% (P = 0.009). This effect persisted after adjusting for covariates (odds ratio: 1.6; 95% CI: 1.01-2.70; P = 0.046). CONCLUSIONS: Weight <30 kg was associated with a small but elevated risk of MAEs. Rates of deferred ablation and cryoablation were similar. Adjusting for factors (including accessory pathway type and location), weight <30 kg remained an independent predictor of acute success.


Assuntos
Feixe Acessório Atrioventricular , Taquicardia Supraventricular , Síndrome de Wolff-Parkinson-White , Adulto , Humanos , Criança , Síndrome de Wolff-Parkinson-White/epidemiologia , Síndrome de Wolff-Parkinson-White/cirurgia , Estudos Retrospectivos , Feixe Acessório Atrioventricular/cirurgia , Sistema de Registros
15.
J Cardiovasc Electrophysiol ; 34(2): 257-267, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36378803

RESUMO

BACKGROUND: Implantable cardioverter defibrillators (ICD) are indicated for primary and secondary prevention of sudden cardiac arrest. Despite enhancements in design and technologies, the ICD lead is the most vulnerable component of the ICD system and failure of ICD leads remains a significant clinical problem. A novel, small-diameter, lumenless, catheter-delivered, defibrillator lead was developed with the aim to improve long-term reliability. METHODS AND RESULTS: The Lead Evaluation for Defibrillation and Reliability (LEADR) study is a multi-center, single-arm, Bayesian, adaptive design, pre-market interventional pivotal clinical study. Up to 60 study sites from around the world will participate in the study. Patients indicated for a de novo ICD will undergo defibrillation testing at implantation and clinical assessments at baseline, implant, pre-hospital discharge, 3 months, 6 months, and every 6 months thereafter until official study closure. Patients may be participating for a minimum of 18 months to approximately 3 years. Fracture-free survival will be evaluated using a Bayesian statistical method that incorporates both virtual patient data (combination of bench testing to failure with in-vivo use condition data) with clinical patients. The clinical subject sample size will be determined using decision rules for number of subject enrollments and follow-up time based upon the observed number of fractures at certain time points in the study. The adaptive study design will therefore result in a minimum of 500 and a maximum of 900 patients enrolled. CONCLUSION: The LEADR Clinical Study was designed to efficiently provide evidence for short- and long-term safety and efficacy of a novel lead design using Bayesian methods including a novel virtual patient approach.


Assuntos
Desfibriladores Implantáveis , Parada Cardíaca , Humanos , Teorema de Bayes , Reprodutibilidade dos Testes , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Resultado do Tratamento
16.
J Am Heart Assoc ; 11(22): e026904, 2022 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-36326051

RESUMO

Background There are few US Food and Drug Administration (FDA)-approved devices specifically aimed at the pediatric patient with arrhythmia. This has led to a high off-label utilization of devices in this vulnerable population. The Pediatric and Congenital Electrophysiology Society (PACES), the international organization representing pediatric and congenital heart disease arrhythmia specialists, developed a task force to comprehensively address device development issues relevant to pediatric patients with congenital arrhythmia. Methods and Results As a first step, the taskforce developed a 26-question survey for the pediatric arrhythmia community to assess providers' understanding of the FDA approval process, specifically in regard to pediatric labeling. There were 92/211 respondents (44%) with a >90% completion rate. The vast majority of respondents believed there was a paucity of devices available for children (96%). More than 60% of respondents stated that they did not understand the FDA regulatory process and were not aware of whether the devices they used were labeled for pediatric use. Conclusions Pediatric electrophysiologists are keenly aware of the deficit of available pediatric devices for their patients. The majority do not understand the FDA approval process and could benefit from additional educational resources regarding this. A collaborative forum including PACES, FDA, patients and their families, and Industry would be an important next step in clarifying opportunities and priorities to serve this vulnerable population.


Assuntos
Arritmias Cardíacas , Cardiopatias Congênitas , Humanos , Criança , Estados Unidos , United States Food and Drug Administration , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Cardiopatias Congênitas/diagnóstico , Cardiopatias Congênitas/terapia , Inquéritos e Questionários , Eletrofisiologia
17.
J Am Heart Assoc ; 11(22): e025121, 2022 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-36346046

RESUMO

Background The objective of this international multicenter study was to investigate both early and late outcomes of cardiac resynchronization therapy (CRT) in patients with a systemic right ventricle (SRV) and to identify predictors for congestive heart failure readmissions and mortality. Methods and Results This retrospective international multicenter study included 13 centers. The study population comprised 80 adult patients with SRV (48.9% women) with a mean age of 45±14 (range, 18-77) years at initiation of CRT. Median follow-up time was 4.1 (25th-75th percentile, 1.3-8.3) years. Underlying congenital heart disease consisted of congenitally corrected transposition of the great arteries and dextro-transposition of the great arteries in 63 (78.8%) and 17 (21.3%) patients, respectively. CRT resulted in significant improvement in functional class (before CRT: III, 25th-75th percentile, II-III; after CRT: II, 25th-75th percentile, II-III; P=0.005) and QRS duration (before CRT: 176±27; after CRT: 150±24 milliseconds; P=0.003) in patients with pre-CRT ventricular pacing who underwent an upgrade to a CRT device (n=49). These improvements persisted during long-term follow-up with a marginal but significant increase in SRV function (before CRT; 30%, 25th-75th percentile, 25-35; after CRT: 31%, 25th-75th percentile, 21-38; P=0.049). In contrast, no beneficial change in the above-mentioned variables was observed in patients who underwent de novo CRT (n=31). A quarter of all patients were readmitted for heart failure during follow-up, and mortality at latest follow-up was 21.3%. Conclusions This international experience with CRT in patients with an SRV demonstrated that CRT in selected patients with SRV dysfunction and pacing-induced dyssynchrony yielded consistent improvement in QRS duration and New York Heart Association functional status, with a marginal increase in SRV function.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Transposição dos Grandes Vasos , Humanos , Adulto , Feminino , Pessoa de Meia-Idade , Masculino , Terapia de Ressincronização Cardíaca/efeitos adversos , Terapia de Ressincronização Cardíaca/métodos , Ventrículos do Coração , Estudos Retrospectivos , Resultado do Tratamento , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia
19.
JACC Clin Electrophysiol ; 8(9): 1165-1172, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-36137726

RESUMO

Children, adolescents, and young adults with conditions such as cardiomyopathies and channelopathies are at higher risk of sudden cardiac death caused by lethal arrhythmias, especially ventricular fibrillation. Timely defibrillation saves lives. Patients thought to be at significantly high risk of sudden death typically undergo placement of an implantable cardioverter-defibrillator. Patients thought to be at lower risk are typically followed medically but do not undergo implantable cardioverter-defibrillator placement. However, low risk does not equal no risk. Compared with the general population, many of these patients are at significantly higher risk for lethal arrhythmias. We make the case that such individuals and families will benefit from having an at-home automatic external defibrillator. Used in conjunction with conventional measures such as training on cardiopulmonary resuscitation, an at-home automatic external defibrillator could lead to significantly shortened time to defibrillation with better overall and neurological survival. We recommend that the cost of such home automatic external defibrillators should be covered by medical insurance.


Assuntos
Reanimação Cardiopulmonar , Desfibriladores , Adolescente , Arritmias Cardíacas/complicações , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Criança , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores/efeitos adversos , Humanos , Fibrilação Ventricular/complicações , Fibrilação Ventricular/terapia , Adulto Jovem
20.
J Am Heart Assoc ; 11(16): e024112, 2022 08 16.
Artigo em Inglês | MEDLINE | ID: mdl-35929446

RESUMO

Background Insertable cardiac monitors (ICMs) are effective in the detection of paroxysmal arrhythmias. In 2014, the first miniaturized ICM was introduced with a less invasive implant technique. The impact of this technology on ICM use in pediatric patients has not been evaluated. We hypothesized an increase in annual pediatric ICM implants starting in 2014 attributable to device miniaturization. Methods and Results A retrospective observational study was conducted using administrative claims from MarketScan Medicaid and commercial insurance claims databases. Use of ICM between January 2013 and December 2018 was measured (normalized to the total enrolled population ≤18 years) and compared with balancing measures (Holter ambulatory monitors, cardiac event monitors, encounters with syncope diagnosis, implantation of implantable cardioverter-defibrillator/pacemaker). Secondary analyses included evaluations of subsequent interventions and complications. The study cohort included 33 532 185 individual subjects, of which 769 (0.002%) underwent ICM implantation. Subjects who underwent ICM implantation were 52% male sex, with a median age of 16 years (interquartile range, 10-17 years). A history of syncope was present in 71%, palpitations in 43%, and congenital heart disease in 28%. Following release of the miniaturized ICM, use of ICMs increased from 5 procedures per million enrollees in 2013 to 11 per million between 2015 and 2018 (P<0.001), while balancing measures remained static. Of 394 subjects with ≥1 year of follow-up after implantation, interventions included catheter ablation in 24 (6%), pacemaker implantation in 15 (4%), and implantable cardioverter-defibrillator implantation in 7 (2%). Conclusions Introduction of the miniaturized ICM was followed by a rapid increase in pediatric use. The effects on outcomes and value deserve further attention.


Assuntos
Desfibriladores Implantáveis , Eletrocardiografia Ambulatorial , Adolescente , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/terapia , Criança , Eletrocardiografia Ambulatorial/métodos , Feminino , Humanos , Masculino , Medicaid , Miniaturização/métodos , Síncope
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...